Kemgard® 911C Comparison to AOM in Cone Calorimeter
Low Smoke Wire and Cable Formula
Application Bulletin #2020
| Cone Calorimetry Data |
Kemgard® 911C |
AOM |
| Average Heat Release (kW/m2) |
52.01 |
50.04 |
| Average Smoke Yield (m2) |
0.052 |
0.052 |
| Peak Heat Release Rate (kW/m2) |
74.70 |
76.65 |
| Peak Heat Release (kJ) |
3.95 |
4.38 |
| Peak Smoke (m2) |
0.095 |
0.125 |
|
Oxyvinyl 240, Halstab H-695 - 7phr, ATH - 30phr, Antimony Trioxide - 3phr, Santicizer 2148 - 20phr, Uniplex FRP 45 - 20phr, Calcium Carbonate - 10phr
Smoke Suppressant added at 20phr
|
Printable Version
 |
All information is believed reliable; however, all recommendations are made without guarantee, since the conditions of use are beyond our control. All products are sold without warranty, expressed or implied, and on the condition that purchasers shall make their own tests to determine the suitability of such products for their purposes and that all risks are assumed by the user. Statements contained herein shall not be construed to be a recommendation to infringe any patent.
|