Kemgard® 911C Lowers Smoke and Improves LOI
Outperforms AOM at Various Loadings
Wire & Cable Formula
Application Bulletin #2060
| Smoke Suppressant |
Control |
Kemgard® 911C |
AOM |
| Loading |
|
10 phr |
20 phr |
30 phr |
10 phr |
20 phr |
30 phr |
| |
|
|
|
|
|
|
|
| NBS Smoke (ASTM E662) |
|
|
|
|
|
|
|
| Flaming Mode |
|
|
|
|
|
|
|
| D90 (ave) |
41 |
25 |
16 |
20 |
45 |
40 |
39 |
| D4.0 (ave) |
247 |
146 |
110 |
109 |
190 |
147 |
164 |
| Dmax (ave) |
530 |
321 |
255 |
218 |
317 |
244 |
240 |
| |
|
|
|
|
|
|
|
| LOI |
33 |
37 |
40 |
41 |
38 |
41 |
43 |
|
Oxyvinyl 240
Halstab H-695 - 7 phr
Santicizer 2148 - 35 phr
Antimony Oxide - 3 phr
ATH - 30 phr
Calcium Carbonate - Varied*
*Control contained 30 phr CaCO3. To maintain constant filler content, the CaCO3 level was reduced to offset addition of smoke suppressants.
|
Printable Version
 |
All information is believed reliable; however, all recommendations are made without guarantee, since the conditions of use are beyond our control. All products are sold without warranty, expressed or implied, and on the condition that purchasers shall make their own tests to determine the suitability of such products for their purposes and that all risks are assumed by the user. Statements contained herein shall not be construed to be a recommendation to infringe any patent.
|