Kemgard® 911C Outperforms AOM in Two Foot Tunnel Test

Two Plasticizer Systems

Application Bulletin #2080

  System 1 System 2
  Kemgard® 911C AOM Kemgard® 911C AOM
Two Foot Tunnel        
Flame Spread (inches) 7.5 8 7.5 7.8
Peak Optical Density 26.8 30.5 39.9 60.6
Cumulative Smoke 936 1323 1083 1929
NBS Smoke (ASTM E662)
Flaming Mode
       
D90 33 69 51 65
D4.0 133 195 166 199
Dmax 257 249 287 277
         
Oxygen Index (ASTM D2863) 47 50 46 47

System 1: 20 phr Santicizer 2148, 20 phr Unitex FRP45
System 2: 20 phr Unitex Frp 45, 20 phr BASF 711P phthalate

Common Ingredients
Oxyvinyl 240
Halstab H-695 - 7 phr
Antimony Oxide - 3 phr
Calcium Carbonate - 10 phr
ATH - 30 phr
Smoke Suppressant - 20 phr

  Printable Version

All information is believed reliable; however, all recommendations are made without guarantee, since the conditions of use are beyond our control. All products are sold without warranty, expressed or implied, and on the condition that purchasers shall make their own tests to determine the suitability of such products for their purposes and that all risks are assumed by the user. Statements contained herein shall not be construed to be a recommendation to infringe any patent.