Kemgard® 911C Outperforms AOM in Two Foot Tunnel Test
Two Plasticizer Systems
Application Bulletin #2080
| |
System 1 |
System 2 |
| |
Kemgard® 911C |
AOM |
Kemgard® 911C |
AOM |
| Two Foot Tunnel |
|
|
|
|
| Flame Spread (inches) |
7.5 |
8 |
7.5 |
7.8 |
| Peak Optical Density |
26.8 |
30.5 |
39.9 |
60.6 |
| Cumulative Smoke |
936 |
1323 |
1083 |
1929 |
NBS Smoke (ASTM E662) Flaming Mode |
|
|
|
|
| D90 |
33 |
69 |
51 |
65 |
| D4.0 |
133 |
195 |
166 |
199 |
| Dmax |
257 |
249 |
287 |
277 |
| |
|
|
|
|
| Oxygen Index (ASTM D2863) |
47 |
50 |
46 |
47 |
System 1: 20 phr Santicizer 2148, 20 phr Unitex FRP45
System 2: 20 phr Unitex Frp 45, 20 phr BASF 711P phthalate
|
|
Oxyvinyl 240
Halstab H-695 - 7 phr
Antimony Oxide - 3 phr
Calcium Carbonate - 10 phr
ATH - 30 phr
Smoke Suppressant - 20 phr
|
Printable Version
 |
All information is believed reliable; however, all recommendations are made without guarantee, since the conditions of use are beyond our control. All products are sold without warranty, expressed or implied, and on the condition that purchasers shall make their own tests to determine the suitability of such products for their purposes and that all risks are assumed by the user. Statements contained herein shall not be construed to be a recommendation to infringe any patent.
|